3
Foster Prep Station Descriptions
The range consists of 2 to 5 door models with a storage capacity ranging from 270 to 720 litres.
The cabinets are manufactured as a one piece foam shell with easy clean stainless steel exterior
All conform to current legislation and exceed the Montreal protocol using zero ODP refrigerants and insulation.
The temperature is controlled by a LAE microprocessor control with digital temperature display.
Easy accessible condensing unit fitted at the rear for ease of servicing.
The standard refrigeration system is integral with an air-cooled condensing unit with the refrigerant distribution
into the evaporator controlled by capillary.
The cooled air is circulated through the evaporator, via the fan into the storage area.
Coated coils prevent corrosion and prolong refrigeration life.
Easy to read temperature display with wipe clean finish.
Wide magnetic gasket giving a positive door seal.
Temperature and Capacities
Model
FPS 2HR
FPS 3HR
FPS 4HR
FPS 5HR
Counter Base Storage Temperature
+1 to +4°C
+1 to +4°C
+1 to +4°C
+1 to +4°C
Pan Storage Temperature (with Lids Fitted)
+3 to +5°C
+3 to +5°C
+3 to +5°C
+3 to +5°C
Nett Capacity (litres)
270
420
570
720
Pan Clear Opening
1058 x 305
1640 x 305
2222 x 305
2804 x 305
Max Number of 1/3 Pans per Opening
6
9
12
16
Door Opening (w x h) Per Door
450 x 604
450 x 604
450 x 604
450 x 604
Door Opening Depth
1345
1345
1345
1345
Shelf Size
417 x 410
417 x 410
417 x 410
417 x 410
Number of Shelves Supplied Per Unit
4
6
8
10
Number OF Castors Supplied
5
5
5
6
Controller Relavance Table
Model
1
st
Serial Number
Issued
Manufacturer
Date from
Counter
E5269275
05.07.2010
Controller Operation
FD2-10 Controller (00-556241)
Probe Evap 2.5M SN4K15H2 (00-556251)
Probe Air 2.5M SN4K15H1 (00-556248)
LCD 5S Display (00-555992)
LCD5 Connecting Ribbon 1.5m (00-555741)
LCD5 Connecting Ribbon 3m (00-555814)
(Normally only used on FPS4 & 5’S Models)
LCD 5S Display (00-555992)
Indicators and Buttons
Symbol
Reason
Button
Use
Alarm
Info / Set Point Button
Thermostat Output
Manual Defrost / Decrease Button
Fan Output
Increase Button / Manual Activation
Defrost Output
Stand-by Button
Activation of 2
nd
parameter set

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Foster FD2-10 and is the answer not in the manual?

Foster FD2-10 Specifications

General IconGeneral
BrandFoster
ModelFD2-10
CategoryController
LanguageEnglish

Related product manuals