FPS Controller Default Parameter Values
Range -50/-9.9…. 19.9/80°C (With INP = SN4 Only)
Minimum Limit for SP setting
Maximum limit for SP setting
Temperature set point to be achieved
Temperature Control mode:
Off/On Thermostat differential
Thermostat run time with faulty T1 probe.
(CT1 = 0 output with faulty T1 will always be off)
Thermostat off time with faulty T1 probe.
(CT2=0 & CT1 = >0 output with faulty T1 will always be on)
Compressor stop delay after door has been opened
(Only if DS = YES)
Defrost function is disabled
Defrost time elapses only in condition of frost accumulation
Time interval between defrosts
Following mains interruption, timer resumes count
Following mains interruption, timer restarts from zero
Defrost end temperature
(Only if T2 = EPO)
Timed off cycle defrost (compressor and heater off)
Electric heater defrost (compressor off, heater on)
Hot gas defrost (compressor and heater on)
Evaporator pump down. Timed pause at start of defrost
Real (actual) air temperature
Last temperature display before start of defrost
The current set point value.