Cleaning and Maintenance
Important: Before cleaning, the unit should be put into standby and then the power supply should be
turned o at the mains. Please do not plug or unplug the unit with wet hands. Only when cleaning has
been completed and the unit is dry should the cabinet be turned back on at the mains.
Suitable P.P.E (Personnel Protecve Equipment) should be worn at all mes.
Regular Maintenance:
> As and when required remove all product from the unit. Clean exterior and interior surfaces with mild
liquid detergent, following the direcons on the pack at all mes. Rinse surfaces with a damp cloth
containing clean water. Never use wire wool, scouring pads/powders or high alkaline cleaning agents i.e
bleaches, acids and chlorines as these may cause damage.
> Condenser Cleaning:
This should take place on a regular basis or as and when required (4 to 6 weeks) by a competent/trained
personnel.
Use a so brush or vacuum cleaner to remove dirt/dust. If there are any stubborn grease deposits le on
or through the condenser, call your supplier to carry out a full service (this is normally chargeable). Failure
to maintain the condenser may invalidate the warranty of the condensing unit and cause premature
failure of the motor/compressor.
Do not use a wire brush to clean the condenser. Vacuum or brush the air lter (where ed).
> All gaskets should be inspected on a regular basis and replaced if damaged. To clean, wipe with a
warm damp soapy cloth followed by a clean damp cloth. Finally thoroughly dry.
Troubleshoong
During normal operaon the display will show either the temperature or one of the following alarm or warning
indicators:
English
Defrost In Progress
Controller In Standby
Keypad Locked
Generic Alarm
Room High Temperature Alarm
Room Low Temperature Alarm
Probe T1 Failure
(Some icons or switches are only visible during adjustment, when acvated by parameters or through operaon/manual selecon).
Before calling your supplier please make sure that:
a. The plug has not come out of the socket and the mains power supply is on i.e. is the controller
illuminated?
b. Check to see if the unit is in standby
c. The fuse for the cabinet is intact
d. The cabinet is posioned correctly – cold or warm air sources are not aecng the performance
e. The condenser is not blocked or dirty
f. The products are placed in the unit correctly
g. Defrost is not in progress or required
If the reason for the malfuncon cannot be idened, disconnect the electrical supply to the unit and contact
your supplier. When requesng a service call, please quote the model and serial number which can be found
on the silver label located on the inside of the unit (starts E......).