1.Drainresidualprotectiveoilfromthesump.
2.Introducelubricantoilintotheengineofthetypeandquantityindi-
catedinthetable3 3
3
- -
-
26 26
26
3.DraintheCFBprotective󰘱uidfromthefuelcircuit,operatingasin-
dicatedatpoint3ofthesection4 4
4
- -
-
60 60
60
.
4.Removetheplugsand/orsealsfromtheintake,discharge,ventila-
tionandbleederholesoftheengine,restoringnormalconditionsof
use.Connecttheturbochargerinlettotheair󰘰lter.
5.Jointhefuelcircuitstothefueltankofthegenset,completingthe
operationsasindicatedinpoint4ofthesection4 4
4
- -
-
60 60
60
.Duringthe
re󰘰llingoperations,connectthefuelreturnpipetoacontainerto
preventanyresidualCFBprotectiveliquidfrom󰘱owingintothetank.
6.Checkand󰘰lltheenginewithcoolantasrequired,degassingifnec-
essary.
7.Starttheengineandletitidleuntilcompletelystabilised.
8.Checkthattheindicationsonthedashboardareplausibleandthat
therearenoalarmsignals.
9.Stoptheengine.
10.RemovethewarningnoticesofENGINEWITHOUTOILfromthe
engineanddashboard.