F3D3 Series Service Manual - Display Menu for H46N Firmware/ 1.11.4
Questions? Call Franke Technical Support Group For Your Area. Copyright 2012 Franke, Inc. All rights reserved.
Parameter Access & Programming
The original F3D3 Models (with H46N
Firmware) were programmed with Factory
Level operating and service diagnostic
parameters that required sequential bore-
down through multiple levels, to check or
make any changes. Using the front
operator interface touch panel & display
to access:
1) Leave unit plugged in.
2) Turn Main Power Switch ON.
3) Lane power must be OFF. Display will
be blank or show current freezer
temperature, depending on the lane.
To Access Factory Level 3 Parameters:
From Standby condition use 3
rd
touchpad to
enter: 3 3 3 3. [The Entry Code]
Special Mode Select
Cust Fact Exit
Press touchpad 2 = Fact(ory)
Factory Access Level
Lev1 Lev3 Exit
3
Enter Password 0 _ _ _
4A
Press touchpad 2 = OK [Icon will move right to
next digit]
Enter Password 0 0 _ _
4B
Press touchpad 2 = OK [Icon will move right to
next digit]
Enter Password 0 0 0 _
4C
Press touchpad 2 = OK [Icon will move right to
last digit], then:
Enter Password 0 0 0 0
4D
Press touchpad 1 = Inc once, to raise to 1,
then:
Enter Password 0 0 0 1
Special Mode Select
(Go to Page 2)
Follow Flow Chart Diagram on pages 2-12 to access Parameters.
Rev. 1 11/2012
NOTE: All programming is done using the
three choice buttons labeled: 1, 2 and 3 above.