Do you have a question about the Franke F3Dn Twin and is the answer not in the manual?
Details warranty terms for Franke-made parts.
Outlines the extended warranty for the compressor.
Lists conditions and parts not covered by warranty.
Explains warranties for third-party manufactured equipment.
Specifies response times for service requests.
Information on authorized service providers in North America.
Details authorized service providers in Europe.
Troubleshooting steps for when the unit has no power.
Steps to diagnose a blank control panel display.
Diagnosing and resolving the low product light issue.
Troubleshooting steps for tare error indicated by "Reset Lane" lights.
Diagnosing time-out errors shown by flashing "Reset Lane" lights.
Steps for when the unit does not dispense fries.
Troubleshooting doors that fail to open for dispensing.
Further troubleshooting for non-opening dispense doors.
Steps to resolve doors that remain open after dispensing.
Diagnosing issues when LOAD READY is on but no product dispenses.
Steps to correct dispensing of too few fries.
Steps to correct dispensing of too many fries.
Troubleshooting dispense door movement issues.
Diagram and parts list for Step 1 assembly.
Diagram and parts list for Step 2 assembly.
Diagram and parts list for Step 3 assembly.
Electrical schematic for the 120V model.
Electrical schematic for the 230V model.
24-Volt wiring diagram for the 120V model.
24-Volt wiring diagram for the 230V model.
Wiring diagram for the Danfoss condensing unit.
Function of the Lane Power touch-pad.
Function of the Manual Dispense touch-pad.
Meaning of the Load Ready indicator light.
Function of the Load Size touch-pad.
Explanation of Reset Lane function and fault conditions.
Indicator for low product level in the hopper.
Fundamental operational and technician requirements.
Critical safety warning about unplugging the unit.
Recommended parts for first-trip fixes.
Continued list of recommended repair parts.
Components included in the 120V Temperature Controller Kit.
Components included in the 230V Temperature Controller Kit.
Contact information for technical support.
List of tools for gasket replacement.
List of tools for assembly replacement.
Procedure to test the Drum Rotor Motor.
Procedure to test the Door Lift Motor.
Procedure to test the Door [Open] Motor.
Information on base-level diagnostic values.
List of tools for drum rotor motor replacement.
List of components in the replacement kit.
List of tools for rotor/motor block replacement.
Contents of the replacement kit.
List of tools for rotor/motor block replacement.
Critical safety warning for electrical shock.
Requirement for load cell calibration after board replacement.
List of tools for chip replacement.
Troubleshooting false low product light indications.
List of tools for sensor adjustment.
Procedure for reversing door hinges for left-side opening.
Troubleshooting door frame alignment issues.
Default load sizes for US and EU/Int. calibration.
How to change factory set load sizes.
Diagnosing and resolving motor noise issues.
List of tools for motor adjustment.
Troubleshooting hopper installation and alignment.
When load cell recalibration is necessary.
How to test lane load cell calibration.
Factory default thermostat setting and resulting temperature.
List of tools for thermostat adjustment.
Troubleshooting high freezer temperatures.
Troubleshooting when the freezer does not power on.
Critical safety warning for electrical shock.
Warning regarding leak detection in evaporator housing.
Compliance note for refrigerant recovery.
Compliance note for refrigerant recovery during TXV/Filter replacement.
Warning about compressor weight and need for assistance.