6 | Installation Franke Kaffeemaschinen AG
36 User manual SB1200 FM CM
Water temperature <25 °C
Connection to the mains water connection G3/8" compression fitting and metal hose l=1500 mm
Only connect with the hose kit provided
The mains water connection must meet the requirements of the technical data and comply with applicable fed-
eral, state, and local regulations.
The mains water connection must have a backflow prevention device.
The mains water connection must be equipped with a shut-off valve and a check valve with an upstream filter
accessible for inspection. It must be possible for the filter to be removed for cleaning.
Water from the household decalcification system must not be used.
Filter with at least 100 loops/inch (UL)
6.3.2 Water quality
Total hardness: 4–8° dH GH (German total hardness)
7–14° fH GH (French total hardness)
4.2–8.3GPG
70–140ppm(mg/l)
Carbonate hardness 3–6°dHKH / 50–105ppm (mg/l)
Acid content/pH value 6.5–7.5pH
Chlorine content < 0.5mg/l
Chloride content < 30mg/l
TDS (total dissolved solids) 30–150ppm(mg/l)
Electrical conductivity (measured) 50–200µS/cm (microsiemens)
Iron content < 0.3mg/l
Color: Clear
Taste: Fresh and pure taste
Aroma: No perceptible aroma
No rust particles in the water
Reverse osmosis: The water must have a dissolved solids content of at least 30-50 ppm (30-50 mg/l) in order
to prevent the boiler being overfilled.
Evaluating the risk of corrosion
The following formula can be used for evaluation:
Calculated conductivity = measured conductivity [μS/cm] – (measured total hardness [dH GH] x constant)
Measured conductivity in μS/cm
Measured total hardness in dH GH
Constant = 30 [μS/cm]/[ dH GH]
Calculated conductivity Risk of corrosion
<200 μS/cm low
200 – 500 μS/cm increased
>500μS/cm high
Calculation example:
Measured conductivity 700 μS/cm
Measured total hardness 18 dH GH