SPECIFICATIONS
Capacities and Selection Data
Floating Air Pro / Premier Cooling Extended Capacity (By System Model)
System Model
Outdoor Air
Temp. (°F DB)
Indoor Air Temp. °F DB / °F WB
80 /67
Cooling BTUs Heating BTUs Power
kBtu/h kW
FPHW363/A/B
32 29.25 20.48 1.09
41 32.72 22.90 1.45
50 33.50 23.45 2.20
59 33.88 23.72 2.46
67 35.27 24.69 2.63
77 36.36 25.45 3.52
82 37.89 26.52 3.59
87 37.20 26.04 3.69
95 32.91 23.04 3.90
104 29.64 20.75 3.65
115 23.63 16.54 3.13
FRHW093/A
32 7.60 5.32 0.21
41 8.41 5.89 0.28
50 9.73 6.81 0.40
59 11.23 7.86 0.50
67 12.94 9.06 0.69
77 14.12 9.89 0.89
82 14.48 10.13 1.04
87 14.27 9.99 1.07
95 13.56 9.49 1.16
104 12.67 8.87 1.25
115 11.62 8.13 1.40
FPHW123/A
32 13.76 9.63 0.33
41 14.12 9.88 0.47
50 14.60 10.22 0.50
59 14.92 10.44 0.70
67 15.38 10.77 0.84
77 15.50 10.85 1.09
82 15.89 11.12 1.15
87 15.73 11.01 1.17
95 15.19 10.64 1.27
104 14.44 10.11 1.38
115 13.31 9.32 1.32