17 PB
Rated cooling connecting
indoor and (DB/WB)
Model Pressure
of gas pipe
connecting
indoor and
outdoor unit
Inlet and outlet pipe tem-
perature of heat exchanger
Fan speed of
indoor unit
Fan speed of
outdoor unit
Compresso
r frequency
(Hz)
Indoor Outdoor PSI T1 (°F) T2 (°F)
80/67 95/75 MMW09Y1J 116-160 PSI 54 to 57 106 to 109 Super High High 48
MM12Y1J 116-160 PSI 50 to 54 109 to 113 Super High High 77
80/67 95/75 MM18Y3J 130-160 PSI 54 TO 57 176 TO 104 Super High High 75
80/67 95/75 MM24Y3J 130-160 PSI 54 TO 57 176 TO 104 Super High High 87
80/66 95/75 MM36Y3J 130-145 PSI 46.8 TO 56.8 127 TO 96.8 Super High High 60
T1: Inlet and outlet pipe temperature of evaporator
T2: Inlet and outlet pipe temperature of condenser
P: Pressure at the side of big valve
Connection pipe length: 24.6ft.
SPECIFICATIONS
Rated Heating con-
necting indoor and (DB/WB)
Model Pressure
of gas pipe
connecting
indoor and
outdoor unit
Inlet and outlet pipe tem-
perature of heat exchanger
Fan speed of
indoor unit
Fan speed of
outdoor unit
Compresso
r frequency
(Hz)
Indoor Outdoor PSI T1 (oF) T2 (oF)
70/60 47/53 MMW09Y1J
536-551
98 to 100 36 to 39 Super High High 54
MM12Y1J 107 to 111 32 to 37 Super High High 78
70/60 47/43 MM18Y3J
362-391
158 to 104 34 to 31 Super High High 90
70/60 47/43 MM24Y3J 158 to 104 34 to 31 Super High High 87
70/- 20/19 MM36Y3J 507 - 550 134.4 to 102 36 to 39 Super High High 58
T1: Inlet and outlet pipe temperature of evaporator
T2: Inlet and outlet pipe temperature of condenser
P: Pressure at the side of big valve
Connection pipe length: 24.6ft.
Figure 212
Cooling Data Sheet in Rated Frequency
Figure 213
Heating Data Sheet in Rated Frequency