EasyManuals Logo

Friedrich MRM09Y1J Service & Parts Manual

Friedrich MRM09Y1J
135 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #97 background imageLoading...
Page #97 background image
97 PB
TROUBLESHOOTING
Malfunction of Communication E6
Start
Correct connection?
Cut o power supply. Check if
connection line of IDU and ODU
and the wire inside electric box
are correctly connected.
IDU matches with that of ODU?
Communication cord is damaged?
Main board matches
with display board? Main board of
Replace IDU's
main board
Malfunction eliminated?
End
Connect the line
according to
wiring diagram.
Match correctly
according to product
specication
Replace
communication
cord
Replace ODU's
main board.
Malfunction eliminated?
Malfunction eliminated?
Malfunction eliminated?
yes
yes
yes
yes
yes
yes
yes
no
no
no
no
no
no
no

Table of Contents

Other manuals for Friedrich MRM09Y1J

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Friedrich MRM09Y1J and is the answer not in the manual?

Friedrich MRM09Y1J Specifications

General IconGeneral
BrandFriedrich
ModelMRM09Y1J
CategoryAir Conditioner
LanguageEnglish

Related product manuals