EasyManuals Logo

Friedrich VRP Series User Manual

Friedrich VRP Series
41 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #13 background imageLoading...
Page #13 background image
13
Wall Plenum Installation
Parts included in Plenum kit:
Outside Plenum (Part A) Divider (Part C)
Inside Plenum (Part B) Bafe (Part D)
Field Supplied Parts:
Sealant, attachment screws, and ashing
are eld supplied. Silicone sealant is recommended.
VRPXWPA-8, VRPXWPB-8 adjust for walls up to 4”- 8” thick.
VRPXWPA-14, VRPXWPB-14 adjust for walls up to 8” - 14” thick
All installations are similar.
Flashing
1”-3” Screws to
attach the plenum
assembly to the wall
studs
Sealant
Shim

Other manuals for Friedrich VRP Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Friedrich VRP Series and is the answer not in the manual?

Friedrich VRP Series Specifications

General IconGeneral
BrandFriedrich
ModelVRP Series
CategoryHeat Pump
LanguageEnglish

Related product manuals