above120ram
fromwall
Refrigerant pipe
hole (left) O g5
above 150ram from
ceiling
1080
432 432
Indoor unit outline
Models 24000 Btu's
Models 30000 Btu's
above 120ram
from wall
above 120ram
from wall
above "E5Omm from ceiling
1250
815 . 257
Refrigerant pipe
hoIe (right) e 95
j--
above120mm
from wall
58
Indoor unit outline
Models 30000 Btu's
Models 36000 Btu's
Fixing the Installation Plate
1. Install the installation plate
horizontally over the structural
parts on the wall using the spaces
indicated on the plate, as shown in
the figure above.
2. In the case of tiled, concrete or
similar walls, create 5 mm-diameter
holes. Place anchorage supports
for the appropriate assembly
screws.
3. Fix the installation plate to the wall
with 8 A type screws.
Attention
Fit the installation Plate and drill
holes in the wall according to the
wall structure and corresponding
mounting points on the installation
plate (Dimensions are in "mm"
unless otherwise stated).
Installation plate
0 @ @