Connect the cable to the indoor unit
1. The inside and ou|side connecting
cable can be connected without
removing the front grille.
2. Conneding cable between indoor unit
and outdoor unit shall be approved
polychloroprene sheathed flexible cord,
type designation H07RN-F or heavier
cord.
3. Liftthe indoor unit panel up, remove
the electrical box cover by loosening the
screw.
4. Ensure the colour of wires of outdoor
unit and the terminal Nos. are the same
fo the indoors respectively.
5. Wrap those cables not conneded with
terminals with insulation tapes, so that
they will not touch any electrical
companents. Securethe cable onto the
control board with the card clamp.
Electrical box
cover
_<18000 btu's CABLE (Cooling model)
Cable code
1Omm
_<18000 btu's CABLE
(Heating and cooling model)
"Cable A" or "Cable B"
cable code Cable code
10mrn 10ram
> 18000 btu's CABLE
(Heating and cooling model)
"Cable C"
Cable code
10ram