Technical data
Acctiva Easy 1202 1204 1206 2403 6/12 12/24
Selectiva 1006 2003 / 1002/200
3
Mains voltage [V AC] 110-230 V 110-230 V 110-230 V 230 V 230 V
Mains voltage tolerance +/-15
%
+/-15 % +/-15 % +/-15 % +/-15 % +/-15 %
Grid frequency 50/60
Hz
50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz
Max. open circuit power
consumption
1.5 W 1.5 W 1.5 W 1.5 W 1.5 W 1.5 W
Nominal output 18 W 36 W 48 W 48 W 18/24 W 36/43 W
Battery voltage [V DC] 12 V 12 V 12 V 24 V 6/12 V 12/24 V
Arithmetic charging cur-
rent
[A DC]
at 230 V
at 110 V
1.5 A
0.95 A
3.0 A
1.9 A
4.0 A
2.5 A
2.0 A
1.25 A
3.0/2.0 A 3.0/1.8 A
Effective current [Aeff.
DC] *)
2.0 A 4.0 A 6.0 A 3.0 A 4.0/3.0 A 4.0/2.5 A
Battery capacity Acctiva
Easy
Selec-
tiva
1-85
Ah
1-85
Ah
2-150 Ah
2-135 Ah
3-200 Ah
3-180 Ah
1.5-100
Ah
2-100 Ah
2-135 Ah
1.5-100
Ah
2-135 Ah/
1.5-90 Ah
2-100 Ah/
1.5-85 Ah
Chargeable cells 6 6 6 12 3/6 6/12
Duty cycle 100% 100% 100% 100% 100% 100%
Charging characteristic IUoU IUoU IUoU IUoU IUoU IUoU
EMC Class EN 61000-6-3 (Class B)
EN61000-6-1
FCC 15 Class B
Protection **) IP20 IP20 IP20 IP20 IP20 IP20
Operating temperature
***)
-20°C to 40 °C (-4°F to 104°F)
Storage temperature -25°C to 80°C (-13°F to 176°F)
Length of time before
safety cut-out trips
Acctiva
Easy
Selec-
tiva
75 h
75 h
75 h
75 h
56 h
75 h
75 h
75 h
29 h 44 h
75 h
Length of time to switch
off if incorrect voltage
selected
10 min 10 min
*) The effective current corresponds to the specifications for conventional battery char-
gers
**) IMPORTANT! For indoor use only, do not expose the charger to rain or snow.
***) The output power may be reduced at higher temperatures (derating).