Troubleshooting
Troubleshooting
Charging terminals connected to wrong poles
Cause Charging terminals connected to wrong poles
Remedy Swap charging terminals round
Charging terminals short-circuited
Cause Short-circuit on the charging terminals
Remedy Rectify short-circuit on the charging terminals
Cause Battery not detected
Remedy Check that charging terminals are properly connected, press
Start/Stop button for 5 seconds
Over-temperature
Cause Over-temperature - charger too hot
Remedy Allow charger to cool down
Cause Air inlets and outlets covered
Remedy Ensure air inlets and outlets are not obstructed
Safety cut-out
Cause Battery faulty
Remedy Check battery
Cause Charger incorrectly set
Remedy Check settings: Ah, voltage
Cause Incorrect battery type (e.g. NiCd), incorrect number of cells
(voltage)
Remedy Check battery type