59
EN
Technical data
General The cooling capacity of a cooling unit depends on
- Ambient temperature
- Delivery head
- Flow rate Q (l/min) - The flow rate Q depends on the length of the interconnecting
hosepack and the diameter of the hose.
FK 5000, FK 5000
MV
* Optional
FK 5000 FK 5000 MV
Mains voltage 400 V AC 200-230/400-480 V AC
Mains voltage tolerance -10% / +10% -10% / +10%
Mains frequency 50 / 60 Hz 50 / 60 Hz
Current input 0.6 / 0.7 A 0.6 / 1.4 A
Cooling power at
Q = 1 l/min + 25 °C (77 °F)
Q = 1l / min + 40 °C (104 °F)
Q = max. + 25 °C (77 °F)
Q = max. + 40 °C (104 °F)
1000 W
800 W
1500 W
1000 W
1000 W
800 W
1500 W
1000 W
Max. delivery head 35 m
114 ft. 9.95 in.
35 m
114 ft. 9.95 in.
Max. delivery rate 3.5 l/min
0.92 gal./min
3.5 l/min
0.92 gal./min
Max. pump pressure 4.2 bar
60.89 psi
4.2 bar
60.89 psi
Pump Centrifugal pump Centrifugal pump
Pump service life approx. 10,000 hrs approx. 10,000 hrs
Coolant capacity 6 l
1.59 gal.
6 l
1.59 gal.
Protection class IP 23 IP 23
Dimensions l/w/h 710/300/230 mm
27.95/11.81/9.06 in.
710/300/230 mm
27.95/11.81/9.06 in.
Weight (without coolant) 13.6 kg
29.98 Ib.
16 kg
35.27 lb.
Flow monitoring* Sensor
error below 0.7 l/min
(0.18 gal./min)
Sensor
error below 0.7 l/min
(0.18 gal./min)
Coolant temperature monitoring* Error above 70 °C
(158 °F)
Error above 70 °C (158
°F)
Mark of conformity CE CE, CSA