EasyManua.ls Logo

Fronius MTG 250d - Water-Cooled Hosepack - MHP 500 D, 700 D W ML; Water-Cooled Hosepack - MHP 700 D W ML M

Fronius MTG 250d
208 pages
Go to English
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Water-cooled
hosepack - MHP
500d, 700d W
ML
MHP 500d W ML MHP 700d W ML
I (ampere) 10 min/40 °C
CO
2
100% D.C.* 500 100% D.C.* 700
I (ampere) 10 min/40 °C
M21
100% D.C.* 400 100% D.C.* 560
Ø
[mm (in.)] 0.8-1.6 (0.032-0.063) 0.8-1.6 (0.032-0.063)
[m (ft.)] 3.35 / 4.35 (11 / 14) 3.35 / 4.35 (11 / 14)
P
min
[W]** 1400 / 1700 1800 / 2200
Q
min
[l/min (gal./
min.)]
1 (.26) 1 (.26)
P
min
[bar (psi.)] 3 (43) 3 (43)
P
max
[bar (psi.)] 5 (72) 5 (72)
* D.C. = Duty cycle
** Lowest cooling power according to IEC 60974-2
Water-cooled
hosepack - MHP
700d W ML M
MHP 700d W ML M
I (ampere) 10 min/40 °C
CO
2
100% D.C.* 700
I (ampere) 10 min/40 °C
M21
100% D.C.* 560
Ø
[mm (in.)] 0.8-1.6 (0.032-0.063)
[m (ft.)] 1.35 / 2.35 / 3.35 (4.4 / 7.7 / 14)
P
min
[W]** 1100 / 1450 / 1800
Q
min
[l/min (gal./
min)]
1 (.26)
P
min
[bar (psi.)] 3 (43)
P
max
[bar (psi.)] 5 (72)
* D.C. = Duty cycle
** Lowest cooling power according to IEC 60974-2
67