EasyManua.ls Logo

Fronius Primo GEN24 3.6 - General Installation Guidelines and Warnings

Fronius Primo GEN24 3.6
208 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
General
Quick-lock sys-
tem
A quick-lock system (3) is used to
mount the connection area cover and
front cover. The system is opened and
closed with a half-rotation (180°) of
the captive screw (1) into the quick-
lock spring (2).
The system is independent of torque.
NOTE!
Danger when using a drill driver.
This may result in the destruction of the quick-lock system due to overtorque.
Use a screwdriver (TX20).
Do not turn the screws more than 180°.
Warning notices
on the device
Technical data, warning notices and safety symbols are affixed to the inverter.
These warning notices and safety symbols must not be removed or painted over.
They warn against incorrect operation which can lead to serious injury and dam-
age.
55
EN

Table of Contents

Related product manuals