EasyManuals Logo

Fronius Primo Installation

Fronius Primo
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #7 background imageLoading...
Page #7 background image
7
Fronius manufac-
turer's warranty
Detailed, country-specific warranty terms are available on the internet:
www.fronius.com/solar/warranty
To obtain the full warranty period for your newly installed Fronius inverter or storage sys-
tem, please register at: www.solarweb.com.
NOTE! Ensure the polarity is correct when connecting the DC cables.
NOTE! For grounding solar module frames or racks, the relevant specifications from the solar module
manufacturer must be taken into account along with national guidelines.
NOTE! Observe the ESD guidelines when handling option cards.
NOTE! If the inverter is installed in Australia or New Zealand (required standard: AS4777.2:2015), the
inverter must not be used as part of a three-phase combination, as there is no communication link bet-
ween the inverters

Other manuals for Fronius Primo

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fronius Primo and is the answer not in the manual?

Fronius Primo Specifications

General IconGeneral
CategoryInverter
AC nominal output3.0 - 8.2 kW
Grid frequency50 Hz / 60 Hz
THD< 3 %
Power factor (cos φac,r)0.85 - 1 ind./cap.
Efficiency98%
Max. input voltage1000 V
MPP voltage range240 - 800 V
Number of DC connections2
Number of MPP Trackers1
Dimensions (H x W x D)645 x 431 x 204 mm
Weight21.5 kg
Protection classIP65
Operating temperature range-40 °C to +60 °C
Warranty5 years
ModelPrimo
AC nominal voltage230 V

Related product manuals