Fire Prevention EN
CAUTION! Risk of damage to inverters and other live photovoltaic system components due to poor or
unprofessional installation.
Poor or unprofessional installation can cause overheating of cables and terminal connections and result
in arcs. These can cause heat damage, which in turn may lead to fires.
Observe the following when connecting AC and DC cables:
- Tighten all terminals to the torque specified in the operating instructions
- Tighten all grounding terminals (PE / GND), including free ones,
to the torque specified in the operating instructions
- Do not overload cables
- Check cables for damage and verify that they are laid correctly
- Take note of the safety instructions, operating instructions and
any local connection regulations
Using fastening screws, always screw the inverter firmly to the wall
bracket to the torque specified in the operating instructions.
Ensure that the fastening screws are tight before starting the inver-
ter!
3
2
2.5 Nm
1
Manufacturer’s instructions regarding connection, installation and operation must always be observed. To re-
duce the hazard potential to a minimum, perform all installation and connection work carefully according to the
instructions and regulations.
Refer to the device operating instructions / installation instructions for the tightening torques to be used at the
relevant terminal connections.

Other manuals for Fronius Primo

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fronius Primo and is the answer not in the manual?

Fronius Primo Specifications

General IconGeneral
CategoryInverter
AC nominal output3.0 - 8.2 kW
Grid frequency50 Hz / 60 Hz
THD< 3 %
Power factor (cos φac,r)0.85 - 1 ind./cap.
Efficiency98%
Max. input voltage1000 V
MPP voltage range240 - 800 V
Number of DC connections2
Number of MPP Trackers1
Dimensions (H x W x D)645 x 431 x 204 mm
Weight21.5 kg
Protection classIP65
Operating temperature range-40 °C to +60 °C
Warranty5 years
ModelPrimo
AC nominal voltage230 V