EasyManua.ls Logo

Fronius PullMig - Page 15

Fronius PullMig
48 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Technical data
PullMig hosep-
ack gas-cooled
I (Amp.) 10 min/40° C
M21 (EN 439)
40 % d.c.* 280
60 % d.c.* 220
100 % d.c.* 170
I (Amp.) 10 min/40° C
C1 (EN 439)
40 % d.c.* 330
60 % d.c.* 270
100 % d.c.* 210
[m]
(ft.)
6 / 8 / 10
(19,6/26,2/32,8)
[V] DC 42
[A] 0,8
[m/min]
(ipm)
0,5 - 18
(19,69 - 787,40)
[mm]
(in.)
0,8 - 1,6
(.032 - .047)
* d.c. = duty cycle
PullMig hosep-
ack water-cooled
I (Amp.) 10 min/40° C
M21 (EN 439)
100 % d.c.* 400
I (Amp.) 10 min/40° C
C1 (EN 439)
100 % d.c.* 500
[m]
(ft.)
6 / 8 / 10
(19,6/26,2/32,8)
P
min
[W]** 1450 / 1800 / 2000 W
Q
min
[l/min]
(gal./min)
1
(.26)
p
min
[bar]
(psi.)
3
(43.5)
p
min
[bar]
(psi.)
5,5
(79.7)
[V] DC 42
[A] 0,8
[m/min]
(ipm)
0,5 - 18
(19,69 - 787,40)
[mm]
(in.)
0,8 - 1,6
(.032 - .047)
* d.c. = duty cycle
** Minimum cooling power in accordance with standard IEC 60974-2