EasyManua.ls Logo

Fronius PullMig - Page 17

Fronius PullMig
48 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
AW2500 AW4000 AW5000 AW7000
I (Amp.) 10 min/40° C
M21(EN 439) - d.c.* 100 % 220 100 % 350 100 % 400 100 % 550
I (Amp.) 10 min/40° C
C1 (EN 439) - d.c.* 100 % 250 100 % 400 100 % 500 100 % 700
[mm]
(in.)
0,6-1,2
(.024-.047)
0,8-1,2
(.032-.047)
1,0-1,6
(.039-.063)
1,0-1,6
(.039-.063)
* d.c. = duty cycle
PullMig - hosep-
ack / torch neck
Voltage rating (V-Peak):
-
for manually guided torches: 113 V
-
for mechanically guided torches: 141 V
The product complies with standard IEC 60974-7.
PushPull Equal-
isation
PushPull equalisation is adjusted in accordance with the Power Source Operating
Instructions, chapter headed „PushPull Unit“