17 G / 2 13V / 1
Y / 3 R / 4
B Dete
C2 G
C1 G 13V O
C1 L C2 L
C1 H C2 H
- St + St
Pin Pin
Plug
Code
Plug
Code
Plug
18p
15
13
11
9
7
5
3
1
18
16
14
12
10
8
6
4
2
Connections for the charging lights on
the optional plug
Pin Function Color
18 13 V supply.
17 The battery is fully charged. Green
16 An error has occurred (common error). Red
15 Lights up: Battery is charging.
Flashing: Charge has been interrupted.
Yellow
13 The battery has already cooled down and is ready for
use.
Blue
If the RGB (LED strip) setting is stored in the menu, the connection (15) (yellow)
is not supported. The normal (conventional external indicators) or RGB (LED
strip) setting for the "External lamp" function is explained in the "Additional
functions" section of the "Display" chapter.
Temperature-
controlled char-
ging
The temperature-controlled charging option continuously regulates the charging
voltage according to the current battery temperature. This significantly extends
the battery-life, especially when used in cold rooms.
Relay board
WARNING!
Danger when using the relay board for safety-critical functions.
This can result in severe personal injury and damage to property.
▶
Do not use the relay board for safety-critical functions.
NOTE!
Danger due to non-compliance with the permissible mains voltage tolerance.
Malfunctions and damage to property may result.
▶
For the relay board option, the input voltage L-N is restricted to a maximum
of 250 V compared to the battery charger.
59