"RI" curve - the "Ah" section is replaced by a setting option for the "Charging
time".
Both the start and end can be set for the charging time. If required, the start
time can be deselected; then the charging time is based exclusively on the spe-
cified end of charge following a manual charge start.
While making the settings, the user is guided through the menu in the same way
as a wizard function.
3
Use the "Up/Down" buttons to select the desired parameter (e.g. "Cells").
4
Press the "Pause/Start" button to confirm the parameter.
5
Use the "Up/Down" buttons to set the desired value (e.g. "24" for the number
of battery cells).
6
Press the "Pause/Start" button to confirm the entry.
If one or more relevant settings for the charging process are changed in configur-
ation mode, another prompt appears when exiting configuration mode, asking
whether the setting in question should be applied.
The following settings must be confirmed when exiting configuration mode:
-
Curve
-
Battery capacity in Ah (RI curve excluded)
-
Number of cells
-
Equalizing charge ON/OFF
-
CAN protocol
Example:
Change to the curve from 3 - IUI (Pb-
WET) to 6 - RI (Pb-WET).
If the setting is not confirmed, the bat-
tery charger returns to configuration
mode and the setting can be changed
to the desired value.
Settings Below is a detailed explanation of the "Settings" menu item, selected under the
aforementioned "Charging settings" menu item. Navigation is carried out as de-
scribed in the "Configuration mode" section.
A list appears with the following selection options:
37