Charging The "Charging" option is suitable for controlling a signal lamp, for example. While
charging is in progress, the corresponding relay automatically picks up.
Charge 50 % In the same way as the "Main Charge Finished" function, the corresponding relay
switches as soon as the battery is charged to 50%.
Charge 80 % In the same way as the "Main Charge Finished" function, the corresponding relay
switches as soon as the battery is charged to 80%.
Charge not com-
plete
The "Charge not complete" option is suitable for controlling an acoustic signal
generator, for example. If the battery is disconnected from the battery charger
before the charging process is completed, the relay switches for an adjustable
time of 1 to 10 seconds.
Charge Finish The "Charge Finish" option is suitable for controlling a signal lamp, for example.
When the configured charging characteristic is complete, the corresponding re-
lay automatically picks up.
Main Charge Fin-
ished
The "Main Charge Finished" option is suitable for controlling a signal lamp, for ex-
ample. At the end of the main charging phase, the corresponding relay automat-
ically picks up.
Cumulative Er-
ror
The "Cumulative Error" option is suitable for controlling a signal lamp, for ex-
ample. Every time an error is detected, the corresponding relay automatically
picks up.
Cumulative error
+ warning
In the same way as the "Cumulative Error" function, the corresponding relay
picks up as soon as an error or warning is present.
Signal Lamp Alternatively to the charging lights, it is possible to connect one or more suitable
lamps to the relay board to indicate the state of charge or the operating status of
the battery charger. The lamps can be designed for a voltage of up to 30 V DC or
up to 250 V AC on a grid that is grounded at the neutral point.
If the lamps are floating, the switching current must not exceed 4 A. A lamp that
is controlled via the 230 V supply relay may be operated at an output current of
max. 1 A.
Immobiliser If the battery charger is installed in a vehicle as an on-board solution, the option-
al immobilizer device prevents unintentional start-up of the vehicle during the
61