Selectiva 16 kW
220 V
WARNING!
An electric shock due to a residual current can be fatal.
Only use a type B residual current circuit breaker for the grid connection of the
device.
Mains voltage (-10% / +30%)
1
)
Optional:
3~ NPE 220 V / 50/60 Hz
3~ PE 220 V / 50/60 Hz
Mains fuse
2)
32 A
Minimum cross-section of the grid lead
Selectiva 4120
Selectiva 4140 / 4160
4 mm² (0.0062 in.²)
6 mm² (0.0093 in.²)
Duty cycle 100%
EMC device class B
Standby consumption 6.9 W
Safety class I
Max. permitted grid impedance Z
max
on
PCC
3)
According to the "Device-spe-
cific data" table below
Degree of protection
4)
IP 20
Overvoltage category III
Operating temperature
5)
-20°C to +40°C
(-4°F to 104°F)
Storage temperature -25 °C to +80 °C
(-13 °F to 176 °F)
Relative humidity Max. 85%
Maximum altitude above sea level 3000 m (9842 ft.)
Mark of conformity According to rating plate
Product standard EN 62477-1
Dimensions L x W x H 647 x 247 x 392 mm
(25.47 x 9.72 x 15.43 in.)
Weight (with standard grid and charging
cable)
34.84 kg (76.81 lb.)
Pollution degree 3
1) The device may be operated on grids that are grounded at the neutral
point with a maximum outer conductor nominal voltage of 220 V.
2) Only use a type B residual current circuit breaker for the grid connection
of the device. The leakage current to ground is less than 3.5 mA.
3) Interface to a 127/220 V and 50 Hz public grid.
4) For indoor use only, must not be exposed to rain or snow.
5) At a high ambient temperature, a power reduction may occur (derating).
66