23
EN-US
Keys and symbols
Controls and Indi-
cators
The keys have capacitive function. Contact with water may affect the function of the keys.
For optimal function, wipe the keys dry with a cloth if necessary.
Item Description
(1) Display
for displaying values, settings and menus
Control and Status LEDs
(2) General Status LED
lights up:
- When a status code is shown on the display (red for error, orange for warn-
ing)
- When grid power feed operation is interrupted
- During troubleshooting (the inverter is waiting to be reset or for an error to
be corrected)
(3) Startup LED (orange)
lights up:
- When the inverter enters the automatic startup or self test phase (as soon
as the solar modules yield sufficient power output after sunrise)
- When the inverter has been set to standby operation in the Setup menu (=
manual shutoff of operation)
- When the inverter software is updated
(4) Operating status LED (green)
lights up:
- When the photovoltaic system is functioning without error after the auto-
matic start-up phase of the inverter
- As long as grid power feed operation is active
Function Keys - Each Has a Different Function Depending on the Selection:
(5) "Left/Up" key
for navigating left and up
(6) "Down/Right" key
for navigating down and right
(7) "Menu/Esc" key
for switching to the menu level
to exit the Setup menu
(8) "Enter" key
for confirming a selection
(1)
(2)
(3)
(4)
(5) (6) (7) (8)