59
EN-US
Fronius Symo 15.0-3 208
Input Data
MPP voltage range
at 208 V 325–850 V DC
at 220 V 340–850 V DC
Input voltage range (at 1000 W/m² / 14°F in an open circuit) 325–1000 V DC
Max. input current
at 208 V 47.8 A
at 220 V 45.7 A
Max. short circuit current of solar modules (I
SC PV
) (MPP1/MPP2) 49.5/37.5 A
Max. recovery current
4)
at 208 V 39.9 A
at 220 V 38.1 A
Output Data
Nominal output power (P
nom
) 15000 W
Max. output power (+104°F) 15000 W
Max. output power (+140°F) 6600 W
Phases 3 ~ NPE
Nominal grid voltage
at 208 V 120 V/208 V
at 220 V 127 V/220 V
Operating range AC voltage -12 +10%
Grid voltage setting range
at 208 V 106–132 V/183–229 V
at 220 V 112–140 V/194–242 V
Nominal output current
at 208 V 41.6 A
at 220 V 39.4 A
Maximum output current
at 208 V 42.0 A
at 220 V 42.0 A
Max. output residual current per duration - A / - ms
Nominal frequency 60 Hz
1)
Total harmonic distortion < 3.5%
Power factor (cos phi) 0 - 1 ind./cap.
2)
General Data
Maximum efficiency 97.30%
CEC efficiency 96.50%
Cooling Controlled forced-air ventilation
Protection class NEMA 4X
Dimensions h x w x d
28.5 x 20.1 x 8.9 in.
725 x 510 x 225 mm
Weight 78.3 lbs. (35.5 kg)
Permissible ambient temperature -40°F to +140°F (-40°C to +60°C)
Permissible storage temperature -40°F to +158°F (-40°C to +70°C)
Permissible humidity 0–100%
Noise emission 72.5 dB(A) (ref. 1pW)
Protection Devices
Reverse polarity protection Integrated
Stand-alone operation protection Integrated