35
EN
Technical Data
General remarks
Mains voltage 3x400 V
Mains voltage tolerance +/- 15 %
Mains fuse protection (slow-blow) 35 A
Mains connection
1)
Restrictions possible
Primary continuous power (100% d.c.
2)
) 12.9 kVA
Cos Phi 0,99
Efficiency 90 %
Welding current range Rod electrode 10 - 380 A
TIG 10 - 380 A
Welding current at 10 min / 40°C 40 % d.c.
2)
380 A
10 min / 40°C 60 % d.c.
2)
360 A
10 min / 40°C 100 % d.c.
2)
320 A
Standard working voltage Rod electrode 20.4 - 35.2 V
TIG 14.5 - 33 V
Max. working voltage Rod electrode 53 V (380 A)
80 V (10 A)
Open-circuit voltage pulsed peak value 95 V
mean value 60 V
Degree of protection IP 23
Type of cooling AF
Insulation class F
Dimensions L x W x H mm 625/290/475
Weight 36.1 kg
1) To 230/400 V, 50 Hz public supply mains
2) d.c. = duty dycle
TP 4000 CEL
NOTE! If the machine is designed to run on a special voltage, the Technical
Data shown on the rating plate apply. The mains plug and mains supply lead,
and their fuse protection, must be dimensioned accordingly.