EasyManua.ls Logo

Fronius TransPuls Synergic 3200 - Page 169

Fronius TransPuls Synergic 3200
212 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
167
EN
EFd | 12.1
Cause: No actual rotational speed value from the wire-feed unit motor
Remedy: Check the actual-value pick-up and the cable connections to and from it, and
replace if necessary
EFd | 12.2
Cause: No actual value rotational speed from the push-pull unit motor
Remedy: Check the actual-value pick-up and the cable connections to and from it, and
replace if necessary
EFd | 15.1
Wire buffer empty
Cause: Counter lever on main wire-feed unit open
Remedy: Close counter lever on main wire-feed unit
Acknowledge service code using Feeder inching button
Cause: Main wire-feed unit slipping
Remedy: Check wearing parts on wire-feed unit
Use suitable feed rollers
Decrease wire braking force
Increase contact pressure on main wire-feed unit
Acknowledge service code using Feeder inching button
Cause: End of wire reached
Remedy: Check whether sufficient wire is available
Acknowledge service code using Feeder inching button
EFd | 15.2
Wire buffer full
Cause: Counter lever on push-pull unit open
Remedy: Close counter lever on push-pull unit
Acknowledge service code using Feeder inching button
Cause: Push-pull unit slipping
Remedy: Check wearing parts for wire feeding
Use suitable feed rollers
Increase contact pressure on the push-pull unit
Acknowledge service code using the Feeder inching button"
Cause: Arc not igniting due to inadequate ground (earth) connection
Remedy: Check the ground (earth) connection
Acknowledge service code using the Feeder inching button
Cause: Arc not igniting due to the wrong welding program setting
Remedy: Select wire diameter and material type in accordance with the material used
(select a suitable welding program). Acknowledge service code using the
Feeder inching button
EFd | 15.3
No wire buffer available
Cause: Connection to wire buffer missing
Remedy: Check connection to wire buffer, check wire buffer control line

Table of Contents

Other manuals for Fronius TransPuls Synergic 3200

Related product manuals