2-8
2. Open the gas supply to the fryer and check all piping, fittings, and gas connections for leaks. A
soap solution should be used for this purpose.
3. Close the fryer drain valve and fill the frypot with water or oil to the bottom OIL LEVEL line at
the rear of the frypot. Light the fryer described in the “Lighting Instructions” topics found in
Chapter 3 of this manual.
DANGER
“Dry-firing” your unit will cause damage to the frypot and can cause a fire. Always
ensure that cooking oil or water is in the frypot before firing your unit.
4. The burner manifold pressure should be checked at this time by the local gas company or an
authorized service agent. The tables below and on the following page list the burner manifold
gas pressures for the various gas types that can be used with this equipment.
Natural Gas Lacq
(G20) under 20 mbar
78
Natural Gas Gronique *
(G25) under 25 mbar
10 11.2
Natural Gas Gronique
(G25) under 20 mbar
10 11.2
Butane/Propane
(G30) at 28/30 or 50 mbar
17 17
Propane
(G31) under 37 or 50 mbar
20.6 20.6
* Belgian G25 = 7,0 mbar (single or dual)
Non-CE Standard
Burner Manifold Gas Pressures
Gas Pressure
Natural
3.20" W.C.
0.80 kPa
Propane
8.25" W.C.
2.5 kPa
5. Check the programmed temperature thermostat setting. (Refer to chapter 1 FilterQuick™
Controller Manual) for the setpoint programming instructions for your particular controller.)
2.5 Converting to another Gas Type
DANGER
This appliance was configured at the factory for a specific type of gas. Converting from
one type of gas to another requires the installation of specific gas-conversion compo-
nents. Conversion instructions are included with conversion kits.
Switching to a different type of gas without installing the proper conversion components
may result in fire or explosion. NEVER ATTACH THIS APPLIANCE TO A GAS SUPPLY
FOR WHICH IT IS NOT CONFIGURED!
AUSTRALIA ONLY
Burner Manifold Gas Pressures
Natural Gas Propane Gas
Orifice MJ/h
TPP Orifice MJ/h TPP
Full Vat
2.92mm 73.8
1.0 kPa 1.95mm 73.8 2.05 kPa
Split Vat
2.84mm
36.9
each
73.8
total
1.0 kPa 1.95mm
36.9 each
73.8 total