EasyManua.ls Logo

Frymaster MJ45 - User Manual

Frymaster MJ45
54 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Performance Pro Series
MJ35-MJ45
Gas Fryers
Installation, Operation and Maintenance Manual
This manual is updated as new information and models are released. Visit our website for the latest manual.
Part Number: FRY_IOM_8196042 09/2018
*8196042*
FOR YOUR SAFETY
Do Not Store or use gasoline
or other flammable vapors
and liquids in the vicinity of
this or any other appliance.
OriginalInstructions
CAUTION
READ THE INSTRUCTIONS BEFORE USING THE FRYER.
Read these instructions for use carefully so as to
familiarize yourself with the appliance before
connecting it to its gas supply.
Keep these instructions for future reference.
Your Growth Is Our Goal

Questions and Answers

  • S
    shane17Aug 17, 2025
    How to fix a Frymaster MJ45 Fryer when the burner will not light?
    • M
      Michael SwansonAug 17, 2025
      The most common cause is that the pilot light is not lit. Try lighting the pilot according to the instructions. Other possible causes include an open drain valve (ensure it's fully closed), no electrical power (verify the unit is plugged in and the circuit breaker hasn't tripped), or no gas supply (check gas line connections and cutoff valves). If these steps don't resolve the issue, the controller might be faulty. If you have a spare controller known to be good, try substituting it. If the fryer then works, order a replacement controller.
  • L
    Leslie SnyderAug 20, 2025
    Why won't my Frymaster MJ45 Fryer CM III.5 go into programming mode?
    • W
      William JonesAug 20, 2025
      The most likely cause is a temporary controller malfunction caused by a voltage surge. Try disconnecting the Frymaster Fryer unit from electrical power, wait at least one minute, and then reconnect the unit to the power supply and turn the controller on. If this doesn't work, the controller may have failed, and you may need to substitute the controller with one known to be good. If the fryer operates normally after the substitution, order a replacement controller.
  • K
    Katrina ClarkAug 26, 2025
    What to do if my Frymaster Fryer CM III.5 displays as it comes out of melt cycle or the heating mode indicator does not come on?
    • S
      Sean RodriguezAug 26, 2025
      First, verify that the setpoint has been properly entered. If the issue persists, a temporary controller malfunction caused by a voltage surge could be the reason. Try disconnecting the unit from electrical power, wait at least one minute, and then reconnect it. If the problem continues, the controller may have failed. If you have access to a known good controller, try substituting it. If the fryer operates normally after the substitution, order a replacement controller.
  • T
    Tony OsborneAug 28, 2025
    What to do if the heating mode indicator is on but Frymaster MJ45 Fryer is not heating properly?
    • A
      Alicia Peterson MDAug 28, 2025
      If the burner is not lit, refer to the troubleshooting steps for the 'Burner will not light' issue. Another possible cause is a failed controller. If you have a spare controller that you know is working, try substituting it for the suspect controller. If the fryer operates normally after the substitution, order a replacement controller.
  • N
    Nathan PerezAug 30, 2025
    What to do if the Frymaster MJ45 Fryer pump won’t start or stops during filtering?
    • C
      Christina WallsAug 30, 2025
      If the pump runs normally after resetting the thermal overload switch, the pump was overheated. Always filter with the cooking oil/shortening at or near frying temperature. Allow the pump motor to cool off for about 10 minutes after filtering two full frypots one after the other. Check the filter paper after each frypot is filtered. Replace the paper if there is a large accumulation of sediment. If the switch is loose, tighten the screws holding it in place, ensuring that when the handle is placed in the ON position, the lever on the microswitch is pressed firmly against the switch. Pump blockages are usually caused by sediment build-up in the pump due to improperly sized or installed filter paper and failure to use the crumb screen.
  • E
    Edward WilsonSep 2, 2025
    What to do if the Frymaster MJ45 power shower is not spraying properly?
    • B
      brian18Sep 2, 2025
      First, ensure the filter paper is properly installed in the filter pan. Also, confirm that O-rings and the gasket on the Power Shower are present and in good condition. If the issue persists, the openings in the Power Shower might be plugged or have solidified shortening. Clean the Power Shower following the instructions.
  • L
    lewissherriSep 5, 2025
    What to do if the Frymaster Fryer is operating normally, but flames are rolling out of the front of the burner?
    • J
      Jose ProctorSep 5, 2025
      Shut the fryer down and remove any obstructions and/or accumulations of carbon in the flue. Also, shut the fryer down and clean the gas valve vent tube.
  • T
    Tyler ArmstrongSep 8, 2025
    What causes a Frymaster Fryer unit to not go into melt cycle or stay in melt cycle continuously?
    • T
      Taylor RobinsonSep 8, 2025
      The most likely cause is a failed melt cycle switch or a defective melt cycle circuit board. The melt cycle switch or melt-cycle circuit board must be replaced.
  • S
    Sean PooleSep 12, 2025
    What to do if the solid-state controller power and trouble lights are on, but the heat light is not, on my Frymaster MJ45 Fryer?
    • C
      Catherine GarciaSep 12, 2025
      If available, substitute controller known to be good for suspect controller. If fryer operates normally, order replacement controller. If the fryer doesn’t operate properly, have the temperature probe circuit tested.
  • O
    Olivia BlackburnSep 13, 2025
    What could be the reasons, that burner does not light in Frymaster MJ45?
    • C
      cody18Sep 13, 2025
      The pilot light may not be lit. Light pilot per instructions. The drain valve may not be fully closed, verify drain valve is fully closed. There may be no electrical power to unit. Verify that unit is correctly plugged in and that circuit breaker is not tripped. There may be no gas being supplied to unit. Verify that the gas line connections are properly connected, that any cutoff valves between the fryer and the gas main are open, and that the main gas cutoff valve is open.

Frymaster MJ45 Specifications

General IconGeneral
ModelMJ45
TypeGas Fryer
Oil Capacity45 lbs
Heating MethodGas
Dimensions15.5" x 30.5" x 47.5"
FrypotStainless steel
CategoryCommercial Fryer
Voltage120V
Electrical Requirements120V, 60Hz
Gas TypeNatural Gas or Propane
Temperature Range200°F - 375°F