2-8
7. Remove the cover of the EZSpark
TM
push-button battery powered ignitor and insert the AAA
battery with the positive end towards the rear of the fryer (see illustration below). Replace the
cover ensuring it is securely attached.
2.5 Connection to Gas Line
DANGER
Before connecting new pipe to this appliance, the pipe must be blown out thoroughly to
remove all foreign material. Foreign material in the burner and gas controls will cause
improper and dangerous operation.
DANGER
When pressure-testing incoming gas supply lines, disconnect the fryer from the gas line
if the test pressure will be ½ PSIG (3.45 kPa, 13.84 inches W.C.) or greater to avoid
damage to the fryer’s gas tubes and gas valve(s).
DANGER
The appliance and its individual shutoff valve must be disconnected from the gas supply
piping system during any pressure testing of that system at test pressures in excess of
½ PSIG (3.5 kPa, 14.07 inches W.C.).
DANGER
The appliance must be isolated from the gas supply piping system by closing its
individual manual shutoff valve during any pressure testing of the gas supply system at
test pressures equal to or less than ½ PSIG (3.5 kPa, 14.07 inches W.C.).