44 INF-TN2FSC-E
8.3 Processingofmountingsurface
Eliminate pitting, corrosion, unevenness, etc. with paint thinner and sandpaper from the pipe
portion where the detector is to be mounted.
Note) In case jute is wound on a pipe, it should be peeled off before the above treatment.
When cast iron pipe is used, grind the sensor mounting surface by using a sander for
smoothness.
Jute is wound
Detector Width
Pipe
Width
Small outer
diameter FSSD1
320 mm or more
Medium size
(standard) sensor
FSSC, FSSD3
540 mm or more
Large size sensor
FSSE
Mounting dimension
(L) + 200 mm or more
High temperature
FSSH
530 mm or more