EasyManua.ls Logo

Fuji Electric FSC-2 - 8.7 How to attach the type FSSE; 8.7.1 How to connect the signal cable

Fuji Electric FSC-2
196 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
INF-TN2FSC-E 57
 
 


 

Cover
 



 



Cable clamp
Conversion cord
 
CAUTION
• Becarefulnottocutyourhandsoretc.bythecover.
• Besuretoturnoffthepowerbeforeconnectingthesignalcabletotheterminal,otherwise
electricshockmayresult.
• Donottightenthescrewstootightly,otherwisethethreadedportionsmaybedamaged.
Propertighteningtorque:80to120[N•cm]
CAUTION
Connectthecorewire(white)ofthesignal
cableto(+)andtheshieldwire(Black)to
(G).