EasyManuals Logo

Fujitsu AB Series A18LATN User Manual

Fujitsu AB Series A18LATN
131 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #53 background imageLoading...
Page #53 background image
(Not defrosted for 10 minutes)
Outdoor fan : Lo
Compressor frequency : 20 Hz
EEV : 480pulse
4-way valve : OFF
Outdoor fan : OFF
Compressor frequency : 70Hz
Heating operation start : Compressor ON
Defrost Indicator:
[Operation lamp]
7 sec ON / 2 sec OFF
Outdoor heat exchanger temperature: Over 10°C
or
Compressor ON time: Over 15 minutes
Defrost end
05-19
Defrost start
3. Defrost Flow Chart
The defrosting shall proceed by the integrating operation time
and outdoor heat exchanger emperature as follows.
Compressor integrating
operation:
Over 17 minutes to
below 62 minutes
Compressor integrating
operation:
Over 240 minutes
Compressor integrating
operation:
Over 62 minutes to
below 240 minutes
Outdoor
heat exchanger
temperature:
Below - 9°C
Outdoor
heat exchanger
temperature:
Below - 5°C
Compressor integrating
operation:
Over 35 minutes to
below 240 minutes
Outdoor
heat exchanger
temperature:
Below - 6°C
Compressor integrating
operation:
Over 240 minutes
Outdoor
heat exchanger
temperature:
Below - 3°C
Outdoor
heat exchanger
temperature:
Below - 3°C
(In case of 1st defrost)
(In case of 2nd and later defrost)
Outdoor fan : OFF
Compressor : OFF
EEV : 480pulse
4-way valve : OFF
Compressor : ON
(Frequency : 70Hz)
AB*A18/ 24LATN AB*A36/ 45LATN
Outdoor temp -
Outdoor heat exchanger
temperature:
Above 5 degC

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu AB Series A18LATN and is the answer not in the manual?

Fujitsu AB Series A18LATN Specifications

General IconGeneral
BrandFujitsu
ModelAB Series A18LATN
CategoryAir Conditioner
LanguageEnglish

Related product manuals