EasyManua.ls Logo

Fujitsu ADUH09LUAS1 - Page 112

Fujitsu ADUH09LUAS1
156 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
CONTENTS
4. CONTROL AND FUNCTIONS
1. Compressor frequency control..................................................................04-1
1-1. Cooling operation ...........................................................................................................04-1
1-2. Heating operation ...........................................................................................................04-3
1-3. Dry operation..................................................................................................................04-4
1-4. Compressor frequency at normal start-up ......................................................................04-5
1-5. Compressor frequency limitation by outdoor temperature ..............................................04-6
2. Auto changeover operation........................................................................04-8
3. Fan control.................................................................................................04-10
3-1. Indoor fan control..........................................................................................................04-10
3-2. Outdoor fan control.......................................................................................................04-13
4. Timer operation control ............................................................................04-16
4-1. →ireless remote control................................................................................................04-16
4-2. →ired remote control ....................................................................................................04-18
5. Defrost operation control .........................................................................04-21
5-1. Defrost operation in heating operation stopped ............................................................04-22
6. Various control..........................................................................................04-23
6-1. Auto restart...................................................................................................................04-23
6-2. MIN. HEAT operation ...................................................................................................04-23
6-3. ECONOMY operation ...................................................................................................04-23
6-4. Fresh air control............................................................................................................04-23
6-5. Compressor preheating ................................................................................................04-24
6-6. External electrical heater control ..................................................................................04-24
6-7. Electronic expansion valve control ...............................................................................04-24
6-8. Drain pump control .......................................................................................................04-25
6-9. Prevention to restart for 3 minutes (3 minutes st) .........................................................04-26
6-10. 4-way valve control.....................................................................................................04-26
6-11. Unit status monitoring and the detected value indication............................................04-27
7. Various protections...................................................................................04-29
7-1. Discharge gas temperature over-rise prevention control ..............................................04-29
7-2. Anti-freezing control (cooling and dry mode) ................................................................04-29
7-3. Current release control .................................................................................................04-30
7-4. Indoor unit fan motor over temperature protection........................................................04-31
7-5. Compressor temperature protection (For 12/18 model)................................................04-31
7-6. Low outdoor temperature protection.............................................................................04-31
7-7. High temperature and high pressure release control....................................................04-32

Table of Contents

Other manuals for Fujitsu ADUH09LUAS1

Related product manuals