M condition
Model name ASU9RL2 ASU12RL2
Capacity
Cooling
Rated
kW 2.64 3.52
Btu/h 9,000 12,000
Min.—Max.
kW 0.5—3.1 0.9—3.7
Btu/h 1,700—10,700 3,100—12,500
Heating
Rated
kW 2.93 4.10
Btu/h 10,000 14,000
Min.—Max.
kW 0.5—3.5 0.9—4.7
Btu/h 1,700—12,000 3,100—16,000
Heating (17°F) * Rated
kW 1.93 2.46
Btu/h 6,600 8,400
Input power
Cooling
Rated
kW
0.83 1.20
Min.—Max. 0.24—1.44 0.23—1.44
Heating
Rated 0.77 1.21
Min.—Max. 0.21—1.49 0.21—1.66
Heating (17°F) * Rated 0.680 0.945
Current
Cooling
Rated A
7.5 10.9
Heating 7.0 11.0
EER Cooling
kW/kW 3.18 2.93
Btu/hW 10.8 10.0
COP Heating
kW/kW 3.80 3.38
Btu/hW 13.0 11.6
SEER Cooling Btu/hW 16.0
HSPF Heating Btu/hW 9.0
Power factor
Cooling
%
96
Heating 96
NOTES:
Specifications are based on the following conditions:
• Cooling: Indoor temperature of 80°F (26.67°CDB)/67°FWB (19.44°CWB), and outdoor temperature of 95°FDB (35°CDB)/75°FWB (23.9°CWB).
• Heating: Indoor temperature of 70°FDB (21.11°CDB)/60°FWB (15.56°CWB), and outdoor temperature of 47°FDB (8.33°CDB)/43°FWB (6.11°CWB).
• *: Heating (17°F): Indoor temperature of 70°FDB (21.11°CDB)/60°FWB (15.56°CWB), and outdoor temperature of 17°FDB (-8.33°CDB)/15°FWB (-9.44°CWB).
• Test conditions are based on AHRI 210/240 2017.
• Pipe length: 25 ft (7.5 m), Height difference: 0 ft (0 m). (Between outdoor unit and indoor unit.)
- 3 -
1. Specifications
WALL MOUNTED
ASU9-12RL2
WALL MOUNTED
ASU9-12RL2