12. Safety devices
*Pressure switch 2: For control device. (Refer to the wiring diagram.)
Type of protection Protection form
Model
AOU24RLXFZH
Circuit protection
Current fuse
(Main PCB)
250 V, 5 A
250 V, 3.15 A
Current fuse
(Near the terminal)
250 V, 10 A
Fan motor protection Temperature thermistor
Activate
251 ±16 °F
(122 ±9 °C)
Fan motor stop
Reset
240
+18
-16
°F
(116
+10
-9
°C)
Fan motor restart
Compressor protection Temperature thermistor
Activate
226 ±4 °F
(108 ±2 °C)
Compressor stop
Reset
176 ±4 °F
(80 ±2 °C)
Compressor restart
Refrigerant circuit
protection
Pressure switch 1
Activate
609 ±15 PSI
(4.2 ±0.1 MPa)
Reset
464 ±22 PSI
(3.2 ±0.15 MPa)