7. Various control
7-1. Auto restart
→hen the power was interrupted by a power failure etc. during operation, the operation contents at
that time are memorized and when the power is recovered, operation is automatically started with
the memorized operation contents.
Operation contents memorized when the power is interrupted
Operation mode
Setting temperature
Fan mode setting
Timer mode and set time (set by wireless remote controller)
Airflow direction setting
Swing
ECONOM↔ operation
10 °C HEAT operation
Outdoor low noise operation
Remote control setting
→LAN LED setting
7-2. MANUAL AUTO operation
→hen the wireless remote controller is lost or battery power dissipated, this function will work without
the remote controller.
→hen MANUAL AUTO button is pressed more than 3 seconds and less than 10 seconds, MANUAL
AUTO operation starts as shown in the table below. To stop operation, press the MANUAL AUTO
button for 3 seconds.
Operation mode Auto changeover
Fan mode AUTO
Timer mode Continuous (no timer setting available)
Setting temperature 24°C
Vertical airflow direction louver setting Standard
S→ING Off
ECONOM↔ Off
Human sensor Off
7-1. Auto restart - (04-25) - 7. Various control