1-5. Rotation number of compressor limitation by outdoor
temperature
The minimum rotation number of compressor is limited by outdoor temperature as below.
Cooling/Dry mode
F zone
38°C
E zone
19°C
D zone
10°C
C zone
B zone
A zone
0°C
-10°C
Model name Outdoor temperature zone
Limitation of compressor
frequency
AO↔G07KGCA
AO↔G09KGCA
AO↔G12KGCA
A zone 36 rps
B zone 36 rps
C zone 28 rps
D zone 1 rps
E zone 1 rps
F zone 20 rps
AO↔G14KGCA
A zone 36 rps
B zone 36 rps
C zone 28 rps
D zone 20 rps
E zone 1 rps
F zone 20 rps
1-5. Rotation number of compressor limitation by outdoor temperature - (04-5) - 1. Rotation number control of compressor