Loading...
Heating mode
F zone
19°C
E zone
5°C
D zone
0°C
C zone
B zone
A zone
-15°C
-20°C
Model name Outdoor temperature zone
Limitation of compressor
frequency
AO↔G07KGCA
AO↔G09KGCA
A zone 37 rps
B zone 37 rps
C zone 36 rps
D zone 15 rps
E zone 1 rps
F zone 1 rps
AO↔G12KGCA
AO↔G14KGCA
A zone 25 rps
B zone 25 rps
C zone 17 rps
D zone 10 rps
E zone 1 rps
F zone 1 rps
1-5. Rotation number of compressor limitation by outdoor temperature - (04-6) - 1. Rotation number control of compressor