4. Capacity table
Capacity tables show each of following values calculated based on the outdoor temperature and the
indoor temperature, under given Airflow Rate (AFR):
For cooling capacity: Total Capacity (TC), Sensible Heat Capacity (SHC), and Input Power (IP)
For heating capacity: Total Capacity (TC) and Input Power (IP)
4-1. Cooling capacity
¢
Model: ARXG22KMLA
AFR
m
3
/h
1,100
Indoor temperature
°CDB 18 21 23 25 27 29 32
°CWB 12 15 16 18 19 21 23
Outdoor temperature
°CDB
TC SHC IP TC SHC IP TC SHC IP TC SHC IP TC SHC IP TC SHC IP TC SHC IP
kW kW kW kW kW kW kW
-15 4.99 3.92 0.57 5.56 3.94 0.58 5.75 4.28 0.58 6.13 4.30 0.59 6.32 4.64 0.59 6.70 4.62 0.60 7.08 4.92 0.60
-10 5.03 3.92 0.48 5.61 3.95 0.49 5.80 4.29 0.49 6.18 4.31 0.50 6.37 4.65 0.50 6.75 4.63 0.51 7.13 4.93 0.51
0 4.91 3.87 0.49 5.46 3.89 0.50 5.65 4.23 0.50 6.02 4.24 0.51 6.21 4.58 0.51 6.58 4.56 0.52 6.96 4.86 0.52
5 4.77 3.81 0.63 5.32 3.84 0.64 5.50 4.17 0.64 5.86 4.19 0.65 6.04 4.52 0.65 6.40 4.50 0.66 6.76 4.80 0.66
10 4.74 3.81 0.61 5.28 3.83 0.62 5.46 4.16 0.62 5.82 4.18 0.63 6.00 4.51 0.63 6.36 4.49 0.64 6.72 4.79 0.64
15 4.59 3.74 0.73 5.11 3.76 0.74 5.29 4.09 0.75 5.64 4.10 0.76 5.81 4.43 0.76 6.16 4.41 0.77 6.51 4.70 0.78
20 5.77 4.27 1.30 6.43 4.30 1.32 6.65 4.67 1.33 7.09 4.69 1.34 7.31 5.06 1.35 7.75 5.04 1.36 8.19 5.37 1.38
25 5.43 4.14 1.45 6.05 4.16 1.47 6.25 4.52 1.48 6.66 4.54 1.49 6.87 4.90 1.50 7.28 4.88 1.52 7.69 5.20 1.53
30 5.08 3.99 1.58 5.66 4.02 1.61 5.85 4.37 1.62 6.24 4.38 1.63 6.43 4.73 1.64 6.82 4.71 1.66 7.20 5.02 1.67
35 4.74 3.86 1.72 5.28 3.88 1.74 5.46 4.22 1.75 5.82 4.23 1.77 6.00 4.57 1.78 6.36 4.55 1.80 6.72 4.85 1.82
40 4.50 3.74 1.86 5.01 3.76 1.89 5.18 4.09 1.90 5.52 4.10 1.92 5.69 4.43 1.93 6.03 4.41 1.95 6.37 4.70 1.97
46 3.69 3.31 1.60 4.11 3.33 1.63 4.25 3.62 1.64 4.53 3.63 1.65 4.67 3.92 1.66 4.95 3.90 1.68 5.23 4.16 1.69
4-2. Heating capacity
NOTE: Values mentioned in the table are calculated based on the maximum capacity.
¢
Model: ARXG22KMLA
AFR
m
3
/h
1,100
Indoor temperature
°CDB 16 18 20 22 24
Outdoor temperature
°CDB °CWB
TC IP TC IP TC IP TC IP TC IP
kW kW kW kW kW
-15 -16 5.60 2.16 5.46 2.21 5.33 2.25 5.20 2.30 5.06 2.34
-10 -11 6.14 2.25 6.00 2.29 5.85 2.34 5.70 2.39 5.56 2.43
-5 -7 6.70 2.32 6.54 2.37 6.38 2.42 6.22 2.47 6.06 2.52
0 -2 7.26 2.40 7.08 2.45 6.91 2.50 6.74 2.55 6.56 2.60
5 3 7.81 2.48 7.63 2.53 7.44 2.58 7.25 2.63 7.07 2.68
7 6 8.40 2.48 8.20 2.53 8.00 2.58 7.80 2.63 7.60 2.68
10 8 8.05 2.34 7.86 2.39 7.67 2.44 7.48 2.49 7.29 2.54
15 10 7.49 2.11 7.31 2.16 7.13 2.20 6.95 2.24 6.77 2.28
20 15 7.04 1.80 6.87 1.83 6.70 1.87 6.53 1.91 6.37 1.94
24 18 7.32 1.78 7.14 1.81 6.97 1.85 6.80 1.89 6.62 1.92