1. Specifications
Type
Duct
Inverter heat pump
Model name ARXG22KMLA
Power supply 230 V ~ 50 Hz
Power supply intake Outdoor unit
Available voltage range 198—264 V
Capacity
Cooling
Rated
kW 6.0
Btu/h 20,500
Min.—Max.
kW 0.9—6.7
Btu/h 3,100—22,900
Heating
Rated
kW 7.00
Btu/h 23,900
Min.—Max.
kW 0.90—8.00
Btu/h 3,100—27,300
Input power
Cooling
Rated
kW
1.78
Max. 2.90
Heating
Rated 1.87
Max. 2.90
Current
Cooling
Rated A
7.8
Heating 8.2
Power factor
Cooling
%
99.2
Heating 99.2
EER Cooling
kW/kW
3.37
COP Heating 3.74
Moisture removal L/h (pints/h) 2.1 (3.7)
Maximum operating current *1
Cooling
A
12.6
Heating 12.6
Fan
Airflow rate
Cooling
HIGH
m
3
/h
1,100
MED 910
LOW 750
QUIET 580
Heating
HIGH 1,100
MED 910
LOW 750
QUIET 580
Type × Q'ty Sirocco fan × 2
Motor output W 106
Recommended static pressure range Pa 30 to 150
Sound pressure level *2
Cooling
HIGH
dB (A)
31
MED 29
LOW 27
QUIET 25
Heating
HIGH 31
MED 29
LOW 27
QUIET 25
Heat exchanger type
Dimensions (H × W × D)
mm
294 × 1,000 × 39.9
Fin pitch 1.40
Rows × Stages 3 × 14
Pipe type Copper tube
Fin type Aluminum
Enclosure
Material Steel sheet
Color —
Dimensions
(H × W × D)
Net
mm
270 × 1,135 × 700
Gross 300 × 1,320 × 790
Weight
Net
kg
35
Gross 43
Connection pipe
Size
Liquid
mm (in)
Ø 6.35 (Ø 1/4)
Gas Ø 12.70 (Ø 1/2)
Method Flare
Drain port
Material Steel
Size mm Ø 35.7 (I.D.), Ø 38.1 (O.D.)
Operation range
Cooling
°C 18 to 32
%RH 80 or less
Heating °C 16 to 30
Remote control (Option)
Wired remote controller, Wireless remote controller, Mobile app*3 (FGLair
™
)
NOTES:
• Specifications are based on the following conditions:
– Cooling: Indoor temperature of 27 °CDB/19 °CWB, and outdoor temperature of 35 °CDB/24 °CWB.
– Heating: Indoor temperature of 20 °CDB/15 °CWB, and outdoor temperature of 7 °CDB/6 °CWB.
– Standard static pressure: 35 Pa.
– Pipe length: 5 m, Height difference: 0 m. (Between outdoor unit and indoor unit.)
• Protective function might work when using it outside the operation range.
• *1: Maximum operating current is the total current of the indoor unit and the outdoor unit.
• *2: Sound pressure level:
– Measured values in manufacturer’s anechoic chamber.
– Because of the surrounding sound environment, the sound levels measured in actual installation conditions might be higher than the specified values here.
• *3: Available on Google Play
™
store or on App Store
®
. Optional WLAN adapter is also required. For details, refer to the setting manual.
- 2 -
1. Specifications
DUCT TYPE
ARXG22KMLA
DUCT TYPE
ARXG22KMLA