4-2. Heating capacity
NOTE:
Values mentioned in the table are calculated based on the maximum capacity.
¢ Model: ASTG09KMTC
AFR
m
3
/h
710
Indoor temperature
16 18 20 22 24
Outdoor temperature
°CDB °CWB
TC IP TC IP TC IP TC IP TC IP
kW kW kW kW kW
-15 -16 2.95 1.18 2.95 1.16 2.92 1.16 2.90 1.17 2.87 1.19
-10 -11 3.49 1.20 3.41 1.22 3.33 1.24 3.23 1.26 3.13 1.29
-5 -7 4.00 1.29 3.91 1.31 3.81 1.34 3.70 1.36 3.58 1.39
0 -2 4.60 1.39 4.49 1.41 4.38 1.44 4.25 1.47 4.11 1.50
5 3 5.27 1.51 5.15 1.52 5.02 1.56 4.87 1.59 4.72 1.63
7 6 5.56 1.55 5.44 1.58 5.30 1.61 5.14 1.64 4.98 1.68
10 8 6.03 1.64 5.89 1.65 5.72 1.68 5.44 1.68 5.14 1.68
15 10 5.50 1.35 5.38 1.36 5.24 1.39 5.09 1.41 4.93 1.45
20 15 5.74 1.18 5.61 1.20 5.47 1.22 5.31 1.24 5.13 1.28
24 18 5.99 1.12 5.86 1.19 5.65 1.17 5.33 1.16 4.92 1.18
¢ Model: ASTG12KMTC
AFR
m
3
/h
770
Indoor temperature
16 18 20 22 24
Outdoor temperature
°CDB °CWB
TC IP TC IP TC IP TC IP TC IP
kW kW kW kW kW
-15 -16 3.40 1.39 3.39 1.36 3.36 1.36 3.34 1.37 3.30 1.40
-10 -11 4.02 1.41 3.93 1.43 3.83 1.46 3.72 1.48 3.60 1.52
-5 -7 4.60 1.51 4.50 1.54 4.39 1.57 4.26 1.60 4.12 1.63
0 -2 5.29 1.63 5.17 1.66 5.04 1.69 4.89 1.72 4.73 1.76
5 3 6.06 1.77 5.93 1.79 5.78 1.83 5.61 1.87 5.43 1.91
7 6 6.40 1.82 6.26 1.85 6.10 1.89 5.92 1.93 5.73 1.97
10 8 6.94 1.92 6.78 1.94 6.61 1.98 6.42 2.02 6.21 2.07
15 10 6.33 1.58 6.19 1.60 6.03 1.63 5.86 1.66 5.67 1.70
20 15 6.61 1.38 6.46 1.41 6.29 1.43 6.11 1.46 5.91 1.50
24 18 6.89 1.32 6.75 1.40 6.50 1.37 6.14 1.36 5.66 1.39
- 7 -
4-2. Heating capacity 4. Capacity table
WALL MOUNTED
ASTG09-12KMTC
WALL MOUNTED
ASTG09-12KMTC