10. Electrical characteristics
Model name AOTG09KMTC AOTG12KMTC
Power supply
Voltage V 240 ~
Frequency Hz 50
Max operating current*
1
A 7.5 9.0
Starting current A 3.5 4.2
Wiring spec. *
2
Circuit breaker current A 10
Power cable
mm
2
1.5
Connection
cable*
3
Cross-
sectional area
mm
2
1.5
Limited wiring
length
m 21
*1: Maximum operating current is the total current of the indoor unit and the outdoor unit.
*2: Selected sample based on Japan Electrotechnical Standards and Codes Committee E0005. As
the regulations of wire size and circuit breaker differ in each country or region, select appropriate de-
vices complied to the regional standard.
*3: Limit voltage drop to less than 2%. If voltage drop is 2% or more, increase cable conductor size.