11. Safety devices
Type of
protection
Protection form
Model
AOTG09KMTC AOTG12KMTC
Circuit
protection
Current fuse (Main PCB)
250 V, 20 A
250 V, 5 A
250 V, 3.15 A
Fan motor
protection
Terminal protection program
Activate
100±15°C
Fan motor stop
Reset
95±10°C
Fan motor restart
Compressor
protection
Terminal protection program
(Discharge temp.)
Activate
110°C
Compressor stop
Reset
After 7 minutes
Compressor restart
Thermal protection program
(Outdoor temp.)
(Only in COOL or DRY mode)
Activate
-15°C
Compressor stop
Reset
-10°C
Compressor restart
- 59 -