6-2. Outdoor unit
¢ Discharge temperature thermistor
Temperature °F (°C) Resistance (kΩ) Voltage (V)
-22.0 (-30.0) 1,013.11 0.06
-12.0 (-25.0) 729.09 0.09
-4.0 (-20.0) 531.56 0.12
5.0 (-15.0) 392.31 0.16
14.0 (-10.0) 292.91 0.21
23.0 (-5.0) 221.09 0.28
32.0 (0.0) 168.60 0.36
41.0 (5.0) 129.84 0.46
50.0 (10.0) 100.91 0.57
59.0 (15.0) 79.12 0.71
68.0 (20.0) 62.55 0.86
77.0 (25.0) 49.84 1.03
86.0 (30.0) 40.01 1.23
95.0 (35.0) 32.35 1.43
104.0 (40.0) 26.34 1.65
113.0 (45.0) 21.58 1.88
122.0 (50.0) 17.79 2.11
131.0 (55.0) 14.75 2.34
140.0 (60.0) 12.30 2.57
149.0 (65.0) 10.32 2.79
158.0 (70.0) 8.69 3.00
167.0 (75.0) 7.36 3.19
176.0 (80.0) 6.27 3.37
185.0 (85.0) 5.36 3.54
194.0 (90.0) 4.60 3.69
203.0 (95.0) 3.96 3.83
212.0 (100.0) 3.43 3.96
221.0 (105.0) 2.98 4.07
230.0 (110.0) 2.60 4.17
239.0 (115.0) 2.27 4.26
248.0 (120.0) 2.00 4.33
6-2. Outdoor unit - (03-89) - 6. Thermistor resistance values