7-3. Forced cooling operation
The outdoor unit may not operate depending on the room temperature.
→hen FORCED COOLING OPERATION button is pressed more than 10 seconds, forced cooling
operation starts as shown in the table below.
Operation mode Auto changeover
Fan mode AUTO
Timer mode Continuous (no timer setting available)
Setting temperature 75.2°F (24°C)
Vertical airflow direction louver setting Standard
Horizontal airflow direction louver setting According to memory position
S→ING Off
ECONOM↔ Off
Human sensor Off
• During the forced cooling operation, it operates regardless of room temperature sensor.
• Operation LED and timer LED blink at the same time during the forced cooling operation.
They blink for 1 second ON and 1 second OFF on both operation LED and timer LED (same as
test operation).
By performing one of the following action, test operation will be canceled:
• Pressing the remote controller START/STOP button
• Pressing FORCED COOLING OPERATION button for 3 seconds
• 60 minutes passed after starting forced cooling operation
NOTE: →hen HEAT operation is selected on the remote controller during forced cooling operation,
heating test run will begin in about 3 minutes.
7-4. MIN. HEAT operation
MIN. HEAT operation performs as below setting when pressing MIN. HEAT button.
Operation mode Heating
Setting temperature 50°F (10°C)
Fan mode AUTO
LED display Economy
Defrost operation Operate as normal
7-5. ECONOMY operation
The ECONOM↔ operation starts by pressing ECONOM↔ button on the remote controller.
The ECONOM↔ operation is almost the same operation as below settings.
Mode Cooling/Dry Heating
Target temperature Setting temperature +2°F (1°C) Setting temperature -2°F (1°C)