1-5. Rotation number of compressor limitation by outdoor
temperature
The minimum rotation number of compressor is limited by outdoor temperature as below.
Cooling/Dry mode
F zone
E zone
D zone
C zone
B zone
A zone
G zone
J zone
H zone
I zone
87.8°F
(31°C)
35.6°F
(2°C)
69.8°F
(21°C)
44.6°F
(7°C)
23.0°F
(-5°C)
5.0°F
(-15°C)
14.0°F
(-10°C)
100.4°F
(38°C)
107.6°F
(42°C)
K zone
55.4°F
(13°C)
Model name Outdoor temperature zone
Limitation of compressor
frequency
AOUH18LMAS1
A zone 55 rps
B zone 50 rps
C zone 36 rps
D zone 34 rps
E zone 30 rps
F zone 26 rps
G zone 19 rps
H zone 19 rps
I zone 21 rps
J zone 24 rps
K zone 29 rps
AOUH24LMAS1
A zone 60 rps
B zone 55 rps
C zone 52 rps
D zone 45 rps
E zone 36 rps
F zone 28 rps
G zone 21 rps
H zone 19 rps
I zone 21 rps
J zone 24 rps
K zone 29 rps
1-5. Rotation number of compressor limitation by outdoor temperature - (04-5) - 1. Rotation number control of compressor
CONTROL AND
FUNCTIONS
CONTROL AND
FUNCTIONS

Table of Contents

Other manuals for Fujitsu ASUH18LMAS

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu ASUH18LMAS and is the answer not in the manual?

Fujitsu ASUH18LMAS Specifications

General IconGeneral
BrandFujitsu
ModelASUH18LMAS
CategoryAir Conditioner
LanguageEnglish

Related product manuals